产品简介: |
|
|
|
Steel processors use water to cool bearings on the |
|
rollers of their continuous casting machines. If the |
|
casting machine loses water flow, the bearings will fail. |
Alarms are required to notify casting machine operators |
of this crucial loss of flow condition. The T21 flow |
|
switch is installed in each cooling water line to ensure |
this critical low-flow alarm. |
|
|
|
The T21 can be used to monitor lube oil on bearings |
|
and gears in rolling mills; and since a single gear costs |
several hundred thousand dollars, its protection is vital |
to the operation of the plant. |
|
|
|
The T21 can also monitor the flow of cooling water on |
pump seals in steel plants and furnaces. |
|
|
详细说明: |
|
|
|
l Wide operating process |
|
|
|
temperature range of |
|
|
|
-100 to 392oF |
|
|
|
l Removable, plug-in electronics |
|
|
|
board |
|
|
|
l Free of all moving parts that |
|
|
|
can stick, coat or fail |
|
|
|
l Self-heating sensor design |
|
|
|
l Application flexibility |
|
|
|
l Simplifies wiring |
|
|
|
l High reliability |
|
|
|
l Improves response time and |
|
|
|
sensor durability |
|
|
|
Input Power 115 VAC or 230 VAC, 50/60 Hz |
|
|
24 VDC (nominal) |
|
|
|
Output Type 5A DPDT @ 250 VAC |
|
|
|
Humidity 99% Non-condensing |
|
|
|
Accuracy +0.5% of set point - 50oF range |
|
|
Set Point Range Gases 0.5 to 500 feet/second |
|
|
(Flow) Liquids 0.01 to 5 feet/second |
|
|
Repeatability +1.0% of set point |
|
|
|
Response Time 0.5 to 10 seconds |
|
|
|
Sensor Length 2 inches to 120 inches* |
|
|
Enclosure Environmental Rating NEMA 4 |
|
|
Conduit Connection 3/4” NPT(F) |
|
|
|
Stability T emperature compensated |
|
|
|
over entire range |
|
|
|
Ambient T emperature Range -40 to 140oF |
|
|
(-40 to 60oC) |
|
|
|
Process T emperature Range -100 to 392oF |
|
|
(-70 to 200oC) |
|
|
|
Process Pressure Range Vacuum to 3000 psig |
|
|